SpaceCheck.
Presence Sensor

Advanced Space presence detection with daylight sensing.

SpaceCheck is an advanced presence detection solution engineered to enhance indoor  environmental control and energy efficiency.
Utilizing state-of-the-art technology, the SpaceCheck sensor is adept at detecting human presence through various signals including movement, slight motion, and breathing. This sophisticated detection capability ensures that the sensor provides accurate and reliable performance, making it an indispensable tool for optimizing energy usage and improving the comfort and security of indoor spaces.
The sensor is ideal for use in a range of applications such as office spaces, residential buildings, and other indoor environments where precise human presence monitoring is crucial.
By integrating the SpaceCheck Sensor into building management systems, facilities can achieve significant energy savings, enhance security measures, and streamline operations.

Product Features

Advanced Detection Capabilities

Employs advanced Microwave technology to detect a wide range of human presence signals, including movement, slight motion, and breathing. This ensures that even the slightest human activities are accurately monitored.

Power Efficiency

Operates on 12V/24V DC with a stand-by power consumption of less than 0.5W, making it an energy-efficient solution

Versatile Output

Features a dry contact, normally open working mode with a resistive load capacity of 36V, 50mA max, suitable for various control applications.

Integrated Daylight Sensor

The built-in daylight sensor adjusts lighting based on ambient light levels with selectable thresholds (5lux, 25lux, 50lux, disable), contributing to further energy savings.

Customizable Settings

All parameters can be configured via DIP switches or remote control, allowing for tailored performance to meet specific application needs

Optimal Mounting

Designed for flush mounting, with a recommended height of 2.5-4 meters and a detection angle of 150°, ensuring comprehensive coverage.

Robust Design

:Built to operate in a wide range of environmental conditions, with an operating temperature range of -25℃ to +50℃ and up to 85% humidity (non-condensing).

Specifications

General

Input Rated Voltage 12/24V DC ±0.5V
Input Stand-by Power <0.5W .
Output Working Mode Dry Contact, Normal Open
Output Load Capacity Resistive (36V, 50mA Max)
Operating Temperature -25 °C to +50 °C
Operating Humidity 0% to 85% (non-condensing)
Storage Temperature -40 °C to +80 °C
Storage Humidity 0% to 85% (non-condensing)
IP Rating IP20
Protection Class Class II
Installation Flush Mounted
Cut Out size Ø65-Ø75mm
Wiring Screw Terminal, Diameter: 0.75-1.5 Sq.mm
Warranty 3 Years

Sensors

Operating Frequency 5.8 Ghz ±75 Mhz, ISM Band
Transmitting Power 0.3mW Max
Hold Time 5s/30s/1Min/3Min/5Min/10Min/20Min/30Min
Detection Area 100%/75%/50%/25%
Daylight Sensor 5lux/25lux/50lux/Disable
Detection Range (Radius) Movement: 4-5m (Speed: 0.3m/s) Slight Motion: 4-5m Breathing: 3-4m
Detecting Angle 150°

Certifications

RegulatoryCE
EnvironmentalRoHS

 

Functions

The sensor detects human walking, slight motion (such as body movement, turn up head and others minor movements) and breathing to realize the detection of human existence in non-sleep state.

  • Movement signal: Major movement for sensor triggering.
  • Slight motion signal: Very small movement even only body motion can be collected
    the indicator flashes once.
  • Breathing signal: When no slight motion signal, only breathing signal can be
    collected, the indicator flashes 3 times by detecting 3 effective breathing signals.

Movement Signal Active

Slight Motion & Breathing Signal Maintain

  • Movement signal: Major movement for sensor triggering.
  • Slight motion signal: Very small movement even only body motion can be collected
    the indicator flashes once.
  • Breathing signal: When no slight motion signal, only breathing signal can be
    collected, the indicator flashes 3 times by detecting 3 effective breathing signals.

1

When ambient light is sufficient, the light will not turn on even when movement signal is detected.

2

When ambient light is insufficient, the light will turn on automatically when movement signal is detected.

3

The body, head and other small movements during normal work can be detected and light will be on.

4

When the sensor fails to detection movement and inching signal, the light will automatically turn off after the delay time.

Wiring

Dimensions (mm)

Installation

  •  Cut a hole of 65-70mm on the ceiling
  •  Open the button of the rotating protective cover
     to the maximum state
  •  Wiring (input & output)
  •  Install the screw of the line clasp and rotate the
    protective cover on the cover
  • Bend the spring clamp backward to push the
    pre-opened hole in the ceiling6. Ensure smooth and reliable installation

Detection Pattern

DIP Switch Setting

1) Detection Area

 12 
IONON100%
IION75%
IIION50%
IV25%

 

2) Detection Area

 345 
IONONON5S
IIONON30S
IIIONON1min
IVON3min
VONON5min
VION10min
VIION20min
VIII30min

 

Note: To achieve the presence sensor function (breath detection), it must set the hold time at least 1
minute(better longer), 5s for motion sensor test only.

3) Daylight Sensor

 67 
IONON5LUX
IION25LUX
IIION50LUX
IVDisable

Note: When set to “Disable”, regardless of whether there is sufficient light or not, the sensor will turn on the
light whenever movement is detected.

4) Indicator Sensor

 8 
IONopen
IIclose

Note: The indicator light is On by default, and can be turned off by DIP switch or remote control LS button.

Factory Settings

Indicator light: On Detection Area: 100% Hold Time: 1min Daylight Sensor: Disable

Initialization
The first power on, sensor enter self-test mode, and the self-test will be completed after 20 seconds to enter the normal working state. During the initialization, the external motion signal will not be detected, remote control signal is not received.

Remote Settings

Application Notice

1) The sensor should be installed by a professional electrician. Please disconnect the power before installing, wiring or changing the setting of the DIP switch.

2) Put the sensor as far as possible from large areas of metal plate, glass and other materials with high medium density to avoid triggering by mistake.

3) Avoid using objects that have been vibrating for a long time around the sensor, such as shaking fans, etc. The vibration signal will be regarded as the motion signal to trigger the sensor.

4) Avoid the detection window of the daylight sensor of the detector irradiated by an invalid light source, which will interfere with the measurement of ambient light.

5) The microwave sensor has a certain penetrating ability to the wall of the building, and the microwave penetrating to the outside of the wall may cause false alarm when it ACTS on the moving objects outside the fortified area. To avoid triggering by mistake, the installation position and appropriate induction range should be selected during installation.

6) The data on detection pattern is typical value tested in factory, the detection range could be affected by moving speed, installation height, motion object and different environment.

Categories